Description
Online double conversion UPS (Successor of Eaton 9130 UPS)
Performance and Availability
- Double-conversion topology. The Eaton 9SX constantly monitors power conditions and regulates voltage and frequency.
- The internal bypass allows service continuity in case of internal fault; a maintenance bypass is also available (as option) for easy replacement of the UPS without powering down critical systems.
- With a 0.9 power factor the 9SX delivers 28% more power than UPS in its class. It powers more servers than other UPSs with equivalent VA ratings and lower power factors.
- Stronger, longer battery life: Eaton ABM® battery management technology uses an innovative three-stage charging technique that extends battery life by up to 50%. 9SX also provides recommended replacement date for batteries.
Manageability
- The new graphical LCD provides clear information on the UPS’s status and measurements on a single screen. Enhanced configuration capabilities are also available.
- The 9SX can meter energy consumption. kWh values can be monitored using the LCD or Eaton’s Intelligent Power® Software.
- Load segment control enables prioritized shutdowns of nonessential equipment to maximize battery runtime for critical devices.
- 9SX offers Serial, USB connectivity, plus an extra slot for an optional communication card. Eaton’s Intelligent Power® Software seamlessly integrates with leading virtualization environments and cloud orchestrations tools.
Flexibility
- One platform, two factors, dozens of choices. Up to 3000 VA of UPS power is packed into only 2U of rack space. The tower option is about the size of a modern, compact PC.
- More runtimes can be added with up to 4 external hot-swappable battery modules, able to run systems for hours if necessary. The additional battery modules are automatically recognized by the UPS.
Technical Specifications
| Model |
9SX2000I
|
| Rating |
2000 VA / 1800W
|
| Form Factor |
Tower
|
| Electrical Characteristics | |
| Technology |
On-line double-conversion with Power Factor Correction (PFC) system
|
| Nominal Voltage |
200/208/220/230/240 V
|
| Input Voltage Range |
200-276V without derating (up to 140-276V with derating)
|
| Input Frequency Voltage |
40-70Hz, 50/60Hz auto selection, frequency converter mode
|
| Connections | |
| Input |
1 IEC C14 (10A)
|
| Outputs |
8 IEC C13 (10A) sockets
|
| Switched outlet group |
2 outlet groups
|
| Batteries | |
| Typical backup times * (minutes)/load | |
| 9SX 2000 (Tower) |
62 @ 300W
36 @ 500W 22 @ 800W 13 @ 1200W 7 @ 1800W |
| 9SX 2000 (Tower) + 1 EBM/+4 EBM |
280/1050 @ 300W;
165/620 @ 500W; 100/390@ 800W; 65/250 @ 1200W; 40/160 @ 1800W |
| Battery Management |
ABM® and Temperature compensated charging method (user selectable), automatic battery test, deep discharge protection, automatic recognition of external battery units
|
| Communications | |
| Communication ports |
1 USB port + 1 serial RS232 port + 1 mini-terminal block for Remote Power Off + 1 mini-terminal block for Output relay
|
| Communication slot |
1 slot for Network-M2, INDGW-M2 or Relay-MS cards
|
| Operating Conditions, Standards and Approvals | |
| Operating temperature |
0 to 40°C
|
| Noise level |
45 dB
|
| Safety |
IEC/EN 62040-1, UL 1778, CSA 22.2
|
| EMC |
IEC/EN 62040 -2, FCC Class B, CISPR22 Class B
|
| Approvals & Markings |
CE /CB report (TUV) / cULus / EAC / RCM / BIS (Tower models only) / KCC (Tower models only)
|
| Dimensions D x H x W / Weight | |
| UPS Dimensions (mm) |
346 x 214 x 412
|
| UPS Weight (kg) |
33.3
|
| EBM dimensions (mm) |
346 x 214 x 412
|
| EBM weight (kg) |
48.7
|
| Customer service & support | |
| Warranty |
2 Years
|
* Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
| Part Numbers | |
| EBM Tower |
9SXEBM96T
|
| 2m battery connection cable (Tower only) |
EBMCBL96T
|
In the interests of continuous product improvement, all specifications are subject to change without notice