Reliability and performance
- The Eaton 9E UPS constantly monitors power conditions and regulates voltage and frequency thanks to the double conversion topology
- Trust a leading manufacturer with decades of experience and high-quality standards: CE compliance certified by external agency (CB report from the TUV)
- Power more servers than most similar UPS because of a 0.8 power factor
- Low audible noise <40dB at typical load
- Wide input voltage range will minimize the battery usage and help to extend battery lifetime.

Manageability
- Get clear information on the UPS’ measurements (load
level, battery level, input/output voltage and frequency) and
synoptic diagram for UPS’ status on a single screen with
the new LCD interface - Easily communicate with the UPS through USB, RS232 serial
or over the network with the optional network card
(Network-M2). Relay cards or Modbus cards are also available - Integrate 9E into all software environments. The Eaton 9E
is delivered with Eaton’s Intelligent Power™ Software and
is compatible with all major OS including advanced
integration in VMware vCenter and Microsoft Hyper-V

Flexibility
- The internal bypass allows service continuity in case of an internal fault
- Extend runtime as you like by adding up to 4 external
battery modules (EBM) for 2kVA and above. For extra-long runtime, XL models with internal supercharger are also available at 3kVA - An addition to previously launched 9E 6-20kVA, Eaton 9E is now available in a wide range of 1kVA to 20kVA

Advance protection for:
- ATM
- Infrastucture
- Industrial and Medical IT
- Networking
- Storage
- Telecom
- Transportation
Eaton 9E UPS
(1) LCD Interface :
Clear information on UPS
status and measurements
(2) 1 USB port + 1 serial port
(3) Slot for Network-M2, INDGW-M2 or
Relay-MS cards

(4) External Battery Module (EBM) connector
(5) IEC Outlets
(6) IEC Inputs
Technical Specifications
| Model | 9E1000i | 9E2000i | 9E3000i |
|---|---|---|---|
| Rating (VA/W) | 1000VA / 800W | 2000VA / 1600W | 3000VA / 2400W |
| Form Factor | Tower | Tower | Tower |
| Electrical Characteristics | |||
| Technology | Online Double-conversion | ||
| Input Voltage | 208V – 240V | ||
| Input Voltage Range w/o using batteries | 100 – 300V | ||
| Output Voltage | 208V – 240V ±1 % | ||
| Output THDU | < 2% for 100% linear load; < 6% for 100% non-linear load | ||
| Input Frequency Range | 40Hz-70Hz, 50/60Hz Auto selection | ||
| Efficiency (Inverter Mode) | up to 91% (Online); 97.5% (Eco Mode) | ||
| Overload Capacity | 105% – 130%: 60s, 130% – 150%: 10s > 150%: > 300ms | ||
| Recharge Time to 90% Capacity | 4 hours |