AWP ALR6000 Alpha RT 6000VA/5400W Double-Conversion Online UPS

75,000.00

Features

  • Rack / Tower design
  • High frequency and true double-conversion
  • DSP digital control technology
  • Input power factor correction (PFC)
  • Wide input voltage range (110 V ~ 300 V)
  • Output power factor 0.9
  • Cold start
  • Auto sensing frequency
  • ECO mode operation for energy saving
  • Selectable output voltage via LCD
  • 50 Hz / 60 Hz frequency conversion mode
  • Selectable battery low voltage via LCD
  • Power-on self test
  • Advanced battery management (ABM)
  • Short circuit and overload protection
  • Automatic charging in OFF mode
  • Fan speed auto control when temperature varies
  • Standard RS232 communication port and RJ45 protection
  • Optional USB / SNMP communication port
  • Optional emergency power off (EPO)
  • Optional extension battery bank
  • Optional N+X redundancy parallel
  • Optional external maintenance bypass

Description

Technical Specifications

Model
ALR6000
Capacity
6000VA / 5400W
Form Factor
Rack/Tower Convertible

Input

Rated Voltage
 208 V / 220 V / 230 V / 240 V
Voltage Range (115 ~ 295) ± 5 Vac, (linear derating between 50% and 100% load);
full load (165 ~ 295) ± 5 V ac
Frequency Range
40Hz~70Hz ± 0.5% ( auto-sense)
Power Factor
≥ 0.99
Bypass Voltage
rated output voltage*73% ~ rated output voltage*115%

Output

Voltage
208 V / 220 V / 230 V / 240 V (settable via LCD)
Voltage Regulation
±1 %
Frequency
Synchronized with utility in mains mode; 50 / 60 Hz ±0.2 Hz in battery mode
Waveform
Sinusoidal
Crest Factor
3:1
Harmonic Distortion
≦ 2% (linear load)
≦ 5% (non-linear load)
Transfer Time
Mains mode to battery mode: 0 ms
Inverter mode to bypass mode: 0 ms
Overload Capacity
105% ~ 125% for 3 mins
125% ~ 150% for 30 s
>150% for 0.5 s

Efficiency

Mains Mode
≥ 92%
Battery Mode
≥ 91%
ECO Mode
≥ 98%

Batteries

DC Voltage
192 V
Built-in Battery of Standard Model
12 V / 7.0 Ah × 16
Charging Current (Max)
Standard Model :1A
Long time model: 1A / 3A / 5A / 8A
Recharge Time
8 Hrs

Alarms

Utility Failure
4 s per beep
Low Battery
1 s per beep
Overload
1 s twice beep
UPS Fault
Long beep

Communications

RS232 (standard) / USB (optional)
Supports Windows 98 / 2000 / 2003 / XP / Vista / 2008 / Windows 7 / 8 / 10
SNMP (optional)
Power management from SNMP manager and web browser

Others

Humidity
20~90% RH @ 0~40℃ (non-condensing)
Noise Level
≦ 55 dB (1m)
Dimensions (W x D x H) (mm)
440 × 580 × 132 (UPS)
440 × 580 × 132 (Battery)
Packaging Dimensions (W x D x H) (mm):
535 × 660 × 215 (UPS)
540 × 685 × 235 (Battery)
Net Weight / Gross Weight (Kg)
16.4 / 20.7 (UPS)
43.6 / 47.1 (Battery)
Warranty
2 Years on UPS, 1 Year on Battery

* Derate capacity to 70% in CUCF mode and to 90% when the output voltage is adjusted to 208Vac
* All specifications subject to change without notice