Description
Kebos Uninterruptible Power Supply
PowerGarde Series 1000VA Online Double Conversion Tower UPS
Features
- True Online Double Conversion
- Comprehensive LCD for ease of monitoring
- Excellent microprocessor-based digital control guarantees high reliability
- Wide input voltage range
- Input power factor correction
- Unity power factor
- Auto sensing frequency
- Cold start function
- Automatic charging in OFF mode
- Intelligent battery management
- Built-in USB & RS-232 communication port
- Optional Network Card for remote monitoring
- Generator compatible

Comprehensive LCD Panel
Input/Output Voltage and Frequency
Battery and Back-up time
Fault, Mute and Mode Operation Status
Loadin Bar Indicator (0-25%; 26-50%; 51-75%; 76-100%)
Technical Specifications
| Model |
KH11-1KVA Plus
|
| Capacity |
1000VA / 1000W
|
| Form Factor |
Tower
|
| INPUT | |
| Nominal Voltage |
208 / 220 / 230 / 240 Vac
|
| Voltage Range | 110-300 Vac (160-300 Vac at 100% load | 110-300 Vac at 50% load) |
| Frequency Range |
50/60 Hz (auto-sensing), 40-70 Hz range
|
| Power Factor |
0.99
|
| OUTPUT | |
| Nominal Voltage |
208 / 220 / 230 / 240 Vac
|
| Voltage Regulation |
+/- 1%
|
| Frequency (Synchronized) |
50 Hz or 60 Hz +/- 0.1 Hz
|
| Transfer Time |
Zero
|
| Output Socket |
4 x Universal Type (Surge Protection & Battery Back-Up)
|
| Waveform |
Pure Sinewave
|
| BATTERY | |
| Battery Type |
2 x 12 V 9Ah Maintenance-Free, Sealed Lead Acid, Leak Proof
|
| Typical Recharge Time |
4 Hours to recover 90-100% capacity
|
| SYSTEM FEATURES | |
| Efficiency |
AC Mode: 89%
Battery Mode: 87% |
| Crest Factor |
3:1 of T.H.D. @ Linear Load
|
| Harmonic Distortion |
≦ 3% of T.H.D. (linear load)
≦ 6% of T.H.D. (non-linear load) |
| Protection |
Discharge, Overcharge, Overload, Short Circuit & Surge Protection
|
| Alarm |
Battery Mode: Sounding every 4 seconds
Low Battery: Sounding every second Overload: Sounding every 0.5 second Fault: Continuously sounding Bypass Mode: sounding every 10 seconds |
| ENVIRONMENTAL | |
| Operating Temperature |
0 to 40 Degrees Celsius
|
| Humidity Range |
0 to 90% (non-condensing)
|
| Noise Level |
Less than 40dB
|
| PHYSICAL | |
| Dimension D x W x H (mm) |
285 x 145 x 240
|
| Weight (kg) |
9.3
|
| STANDARDS | |
| Safety |
IEC/EN62040-1
IEC/EN60950-1 |
| EMC |
IEC/EN62040-2
IEC61000-4-2 IEC61000-4-4 IEC61000-4-5 IEC61000-4-6 IEC61000-4-8 |
| PRODUCT SUPPORT | |
| Warranty |
Two (2) Years Warranty on UPS Electronics and One (1) Year on Battery
|
General Usage Guidelines:
UPS and its batteries are covered with respective standard warranty, given that:
- Indoor use only and recommended room temperature should be 20 to 25 degrees Celsius only.
- Lower than 20 degrees Celsius reduces battery capacity while higher than 25 degrees Celsius shortens battery lifespan
- Must not expose to direct sunlight, dust, liquid and any other environmental factors that are harmful to UPS and its batteries.
- Unauthorized personnel should not execute any repair on UPS external and internal physical parts including batteries.
- Acts of Nature (Rain/Typhoon, Earthquake, and the like), Fire, and human made errors (from unauthorized personnel) will not be covered of the warranty.
- Air Conditioning Unit Blowers must not be pointed directly at UPS & its Battery Cabinets.
- Do not connect non-IT equipments such as hair blower, flat iron, rice cooker, electric fan, floor polisher & other motorized/heat-producing appliances
In the interests of continuous product improvement, all specifications are subject to change without notice.